Save this project to account
GrantedProtected structureDecision recorded

Protected structure, No. 91 Camden Street Lower, Dublin 2

Dublin 2, Dublin · Dublin City Council · Plan 3766/24 · PB ref PB-10000195229

PROTECTED STRUCTURE: No. 91 Camden Street Lower, Dublin 2 which is a protected structure, RPS. 1159. At the rear there are two returns and a yard linked by right of way to the street at Camden Row. The development consists of: (a) At Roof Level: taking down and re-building existing chimney stack, rebuilding the existing...

Indicative value €250k–500k PB indicative band
Units applied for Not listed public application record
Floor area 256 m² published reliable figure
Decision 21 May 2025 public planning date
Commenced None indexed public commencement index
Decision-stage scope

The public decision state is shown, but conditions and later amendments can still change delivery scope.

Protected structure

The protected-structure designation is source evidence and can shape specification and method.

Not procurement evidence

No tender, award, contractor appointment, supplier appointment or procurement timetable is inferred.

Opportunity & supplier intelligence

What is known, and what may happen next

Source-linked

Timing is a planning-stage outlook, not a tender, award, contractor appointment, supplier appointment or guaranteed procurement date.

Likely procurement timing Post-decision monitoring

A planning decision is recorded and no linked commencement is indexed. Conditions, procurement and start timing remain unconfirmed.

Decision date 21 May 2025. / Confidence: Low
Decision GRANT PERMISSION

Decision date 21 May 2025.

Commencement activity No linked activity indexed

No commencement indexed / This is an index state, not proof that no works have started.

Source limited
Drawings availability Drawing availability not indexed

No drawing entry is available in this lead's bounded document evidence.

Source limited

Confirmed application scope

PROTECTED STRUCTURE: No. 91 Camden Street Lower, Dublin 2 which is a protected structure, RPS. 1159. At the rear there are two returns and a yard linked by right of way to the street at Camden Row. The development consists of: (a) At Roof Level: taking down and re-building existing chimney stack, rebuilding the existing original brick chimney and construction of new DPC where stack breaks the roof slope to prevent falling damp, re-using the existing bricks and clay pots, with a new lime mortar flaunched capping...

Ref 3766/24 Source-linked Official application description for exact planning reference 3766/24

Public source roles

No named firm role is published in this panel's source contract. PlanningBrief does not infer a contractor or supplier.

Explicit source signals only

0 packages

No work package meets the explicit source, reference and locator threshold. PlanningBrief does not pad this list with generic trades.

Confidence & provenance 0 official sources
Authority
Dublin City Council
Exact reference
3766/24
Evidence reviewed
2 Jun 2026
Confidence
Source-linked

Facts come from the indexed public planning record and any bounded structured document evidence. No request-time official fetch, tender, award or appointment inference is used.

Application-stage scope

What the public record evidences

3 source-supported signals
Protected structure

Protected structure

The public application record identifies protected structure in the submitted planning scope.

3766/24Explicit application record
Conservation

Protected-structure / conservation scope

The public application description explicitly references protected-structure / conservation scope.

3766/24Explicit description signal
Services

Services / drainage scope

The public application description explicitly references services / drainage scope.

3766/24Explicit description signal

Only source-supported scope signals are shown; generic trade padding is omitted.

Project facts

Named source parties

Promoter
not included in reference feed
Planning agent
not included in reference feed
Official description

Application text

PROTECTED STRUCTURE: No. 91 Camden Street Lower, Dublin 2 which is a protected structure, RPS. 1159. At the rear there are two returns and a yard linked by right of way to the street at Camden Row. The development consists of: (a) At Roof Level: taking down and re-building existing chimney stack, rebuilding the existing original brick chimney and construction of new DPC where stack breaks the roof slope to prevent falling damp, re-using the existing bricks and clay pots, with a new lime mortar flaunched capping. (b) At Ground Floor Level - Change of use from retail/deli to cafe/restaurant (c. 86.9 sq.m) including: removal of existing floor slab and replacement with a limecrete insulated slab, careful refurbishment of cast-iron columns and downstand beams and application of intumescent fire proofing protection to metal structure to comply with fire officers requirements, careful refurbishment and repair of period meat carcass hanging systems and T&G timber wall linings, provision of a new glazed corridor to allow for dual access to the café/restaurant and protected stairs to upper floors. Removal of non-original internal stairs to the rear return and rebuilding of compliant stairs in same location, provision of external seating area to the rear for use with proposed café/ restaurant (22.4 sq.m). (c) At First Floor Level - Change of use from retail/office to café/restaurant (c. 87.0 sq.m) including: two existing rooms to the main building from office/retail use to café seating and lobby. To the two rear return: two existing rooms to use as visitor restrooms, staff facilities, kitchen and ancillary space/uses associated with the cafe / restaurant. Removal of non-original internal stairs to the rear return and rebuilding of compliant stairs in same location. (d) At Second Floor Level - Change of use from office associated with the retail/deli use to art gallery use (c. 52.7 sq.m). (e) At Attic Level, restoration of historic cruciform oak-beam roof structure to main building and reinstatement of timber sheeting to the underside of sloped roof, removal of 7.5 sq.m of non-original timber ceiling joists to provide a double height space to the art gallery, allowing a better internal appreciation of restored cruciform roof. (f) Externally to the Front Elevation: restoration and repair of Dutch Billy front gable and wall façade including removal of non-original sand/cement render and replacement with breathable lime render. To the Ground Floor Shopfront: careful restoration of historic features including awning refurbishment and reinstatement, removal of non-original stainless steel vent over length of shopfront, refurbishment of existing front door, addition of vertical mullions and servery hatch in shopfront, replacement of existing glazing with histo-glass type or similar approved 'thin' double glazing. Restoration of sliding sash windows to the front façade first and second floors, with historically correct 6 over 6 pane of with histo-glass type or similar approved 'thin' double glazing, removal of modern poor quality timber windows to rear façade and replacement with historically correct 4 over 4 pane of with histo- glass type or similar approved 'thin' double glazing, replacement of existing attic window to rear with historically correct vertical sliding timber sash window. Careful restoration and repair of original lunette window to front façade at attic level. Removal of existing modern gate to rear courtyard area and construction of painted mild steel gate and side panels with a contemporary design, etched and painted, between café external seating space and abattoir area to No. 3 Camden Row. Removal of existing services and replacement with new energy efficient services including UV filtration system extract to rear return. All associated refurbishment works to the interior and exterior: Completion of repairs and renovation of historic/modern fabric as detailed in the Conservation Methodology Statement in compliance with Conservation Best Practice. Together with all associated and ancillary works to those described above.

Source-aware chronology

Application to site progress

Empty lanes explain their state.
PlanningCouncil planning register
  1. Applied 27 May 2024 3766/24
  2. Decision Grant Permission 21 May 2025
AppealsAn Coimisiún Pleanála
  1. Appeal No appeal indexed No public appeal record is indexed against this application.
CommencementPublic commencement index
  1. Commenced No commencement indexed No reliable public commencement record is indexed against this permission.
CompletionPublic completion projection
  1. Completed Completion not recorded No privacy-cleared exact completion certificate is linked to this permission. Absence is not evidence that the project is incomplete.
Evidence register

Source, scope and limits

Public planning record
Application description and scale 3766/24

PROTECTED STRUCTURE: No. 91 Camden Street Lower, Dublin 2 which is a protected structure, RPS. 1159. At the rear there are two returns and a yard linked by right of way to the street at Camden Row. The development consists of: (a) At Roof Level: taking down and re-building existing chimney stack, rebuilding the existing original brick chimney and construction of new DPC where stack breaks the roof slope to prevent falling damp, re-using the existing bricks and clay pots, with a new lime mortar flaunched capping. (b) At Ground Floor Level - Change of use from retail/deli to cafe/restaurant (c. 86.9 sq.m) including: removal of existing floor slab and replacement with a limecrete insulated slab, careful refurbishment of cast-iron columns and downstand beams and application of intumescent fire proofing protection to metal structure to comply with fire officers requirements, careful refurbishment and repair of period meat carcass hanging systems and T&G timber wall linings, provision of a new glazed corridor to allow for dual access to the café/restaurant and protected stairs to upper floors. Removal of non-original internal stairs to the rear return and rebuilding of compliant stairs in same location, provision of external seating area to the rear for use with proposed café/ restaurant (22.4 sq.m). (c) At First Floor Level - Change of use from retail/office to café/restaurant (c. 87.0 sq.m) including: two existing rooms to the main building from office/retail use to café seating and lobby. To the two rear return: two existing rooms to use as visitor restrooms, staff facilities, kitchen and ancillary space/uses associated with the cafe / restaurant. Removal of non-original internal stairs to the rear return and rebuilding of compliant stairs in same location. (d) At Second Floor Level - Change of use from office associated with the retail/deli use to art gallery use (c. 52.7 sq.m). (e) At Attic Level, restoration of historic cruciform oak-beam roof structure to main building and reinstatement of timber sheeting to the underside of sloped roof, removal of 7.5 sq.m of non-original timber ceiling joists to provide a double height space to the art gallery, allowing a better internal appreciation of restored cruciform roof. (f) Externally to the Front Elevation: restoration and repair of Dutch Billy front gable and wall façade including removal of non-original sand/cement render and replacement with breathable lime render. To the Ground Floor Shopfront: careful restoration of historic features including awning refurbishment and reinstatement, removal of non-original stainless steel vent over length of shopfront, refurbishment of existing front door, addition of vertical mullions and servery hatch in shopfront, replacement of existing glazing with histo-glass type or similar approved 'thin' double glazing. Restoration of sliding sash windows to the front façade first and second floors, with historically correct 6 over 6 pane of with histo-glass type or similar approved 'thin' double glazing, removal of modern poor quality timber windows to rear façade and replacement with historically correct 4 over 4 pane of with histo- glass type or similar approved 'thin' double glazing, replacement of existing attic window to rear with historically correct vertical sliding timber sash window. Careful restoration and repair of original lunette window to front façade at attic level. Removal of existing modern gate to rear courtyard area and construction of painted mild steel gate and side panels with a contemporary design, etched and painted, between café external seating space and abattoir area to No. 3 Camden Row. Removal of existing services and replacement with new energy efficient services including UV filtration system extract to rear return. All associated refurbishment works to the interior and exterior: Completion of repairs and renovation of historic/modern fabric as detailed in the Conservation Methodology Statement in compliance with Conservation Best Practice. Together with all associated and ancillary works to those described above.

AuthorityDublin City Council
Reference3766/24
StatusChecked 2 Jun 2026
Open official record