Works consist of internal alterations, reconfiguration, and fire safety upgrades of an existing residential property from an 8 bedroom residence to an 8-bedroom, shared residential property. For the purposes of the Building Regulations (specifically Technical Guidance Document B - Fire Safety), the building is categorized under Purpose Group 2(b) ('Other Residential'). Scope of Works Includes: Construction of non-loadbearing fire-rated stud partition walls to form bedroom/en-suite facilities. Installation of an upgraded, fully addressable mains-powered Fire Detection and Alarm System to IS 3218 (Type L2/L1). Installation of an Emergency Lighting System throughout internal escape routes to IS 3217. Upgrades to compartmentation and internal escape routes, including the installation of FD30S fire door assemblies fitted with self-closing devices, intumescent strips, and cold smoke seals. Provision of specialist passive fire-stopping to all mechanical and electrical service penetrations. Omission/removal of the external steel fire escape stairs and associated minor external window/door adjustments to the rear elevation. All works are internal or minor external items and do not involve structural footprint extensions

Carlow / Carlow / Carlow, Carlow

Create alert Official file
Est. value Not listed
Units Not listed
Floor area 280 m²
Commenced 4 Sep 2026

Key facts

Lead summary

Commenced date
4 Sep 2026
Local authority
Carlow County Council
Source reference
SN0014736CW
Floor area
280 m²
Lead lane
Current BCMS commencement

Official description

Verbatim source text

Works consist of internal alterations, reconfiguration, and fire safety upgrades of an existing residential property from an 8 bedroom residence to an 8-bedroom, shared residential property. For the purposes of the Building Regulations (specifically Technical Guidance Document B - Fire Safety), the building is categorized under Purpose Group 2(b) ('Other Residential'). Scope of Works Includes: Construction of non-loadbearing fire-rated stud partition walls to form bedroom/en-suite facilities. Installation of an upgraded, fully addressable mains-powered Fire Detection and Alarm System to IS 3218 (Type L2/L1). Installation of an Emergency Lighting System throughout internal escape routes to IS 3217. Upgrades to compartmentation and internal escape routes, including the installation of FD30S fire door assemblies fitted with self-closing devices, intumescent strips, and cold smoke seals. Provision of specialist passive fire-stopping to all mechanical and electrical service penetrations. Omission/removal of the external steel fire escape stairs and associated minor external window/door adjustments to the rear elevation. All works are internal or minor external items and do not involve structural footprint extensions

Verify against official source

Likely trades & supplier leads

Inferred from scheme type and scale

Review source file
Create alert