Planning case SD15A0343

South Dublin County Council · SD15A0343 · Clondalkin, Dublin

Latest linked evidence

Notified commencement · 2016-03-22

Provision of 2 single storey data centres (DUB07 & DUB08) immediately west of existing data centre (DUB06). Each data centre will contain the following; offices, computer and associated support areas, electrical component rooms, plant and associated equipment. Gross floor area of each c.16,900sq.m (c.33,800sq.m in total). The height of each data centre will range between c.6.5m & c.13m high. Also proposed are ancillary site works for connection to infrastructural services, as well as fencing, landscaping, perimeter service roads around the buildings. Car parking to provide a total of 257 spaces (including 5 universal accessible spaces). Provision of 10 bicycle parking spaces. Ancillary buildings to include: | New Sprinkler Tank: 12m DIA x 6m H | New Cooling Water Tank: 25m L x 16m W x 4m H | New Pumphouse 1: 10.38m L x 8.5m W x 4.525m H | New Pumphouse 2: 10.38m L x 8.5m W x 4.525m H The buildings / parts of the buildings are intended to be completed over several phases and will have multiple certificates of compliance on completion.

This page connects records for one planning case. Separate permissions, amendments and phases may belong to a wider development. A notified commencement date does not confirm that building work started.

Source history

Timeline

  1. Planning application received

    SD15A0343

    Official source

  2. Planning decision

    SD15A0343

    Permission granted

    Official source

  3. Grant date recorded

    SD15A0343

    Official source

  4. Notified commencement

    Commencement notice

    Provision of 2 single storey data centres (DUB07 & DUB08) immediately west of existing data centre (DUB06). Each data centre will contain the following; offices, computer and associated support areas, electrical component rooms, plant and associated equipment. Gross floor area of each c.16,900sq.m (c.33,800sq.m in total). The height of each data centre will range between c.6.5m & c.13m high. Also proposed are ancillary site works for connection to infrastructural services, as well as fencing, landscaping, perimeter service roads around the buildings. Car parking to provide a total of 257 spaces (including 5 universal accessible spaces). Provision of 10 bicycle parking spaces. Ancillary buildings to include: | New Sprinkler Tank: 12m DIA x 6m H | New Cooling Water Tank: 25m L x 16m W x 4m H | New Pumphouse 1: 10.38m L x 8.5m W x 4.525m H | New Pumphouse 2: 10.38m L x 8.5m W x 4.525m H The buildings / parts of the buildings are intended to be completed over several phases and will have multiple certificates of compliance on completion.

    Quantity not established for this notice.

    · Notice evidence

What this record establishes

Only exact linked records appear here. A missing appeal, commencement or completion entry means that evidence has not been established on this page. It does not prove that the event never happened.

Planning scale and individual notice or phase quantities remain separate. Notice quantities are not added into a development total or completion percentage.