Connected planning records

Planning case 2660904

Galway County Council · 2660904

Latest linked evidence

Planning decision · 2026-07-28

2660904 · Conditional permission

This page connects records for one planning case. Separate permissions, amendments and phases may belong to a wider development. A notified commencement date does not confirm that building work started.

Reviewed build intelligence

What the documents establish

Government document review

The July decision amends parent 24/60466 to provide ground-floor commercial space and 12 tourism guest bedrooms upstairs. Those rooms are not permanent homes.

2 official documents inspected · Checked 2026-09-07 · Official file index

The amendment provides 12 guest bedrooms within the parent building

Amendment decision for parent 24/60466

What the evidence says
The 28 July decision amends permission 24/60466, retaining commercial use at ground floor and adding 12 guest bedrooms on the upper two floors. Condition 1 carries forward the parent terms and effective period except where amended; condition 3 restricts the accommodation to tourism and prohibits permanent residence.

Why it may matter — interpretation
Commercial and hospitality suppliers should follow the changed internal and facade scope without counting 12 guest rooms as 12 additional homes.

What is not established
Final grant, construction progress, business opening and housing supply are not established.

Inspect the evidence

Amendment decision notification and conditions · p.1
12 guest bedrooms · Issued 2026-07-28 · Signed 28 July; notification expressly not final grant · Checked 2026-09-07

12 guest bedrooms

Amendment decision notification and conditions · p.2
Conditions 1 and 3 · Issued 2026-07-28 · Signed 28 July; notification expressly not final grant · Checked 2026-09-07

Conditions 1 and 3

The comparison drawing increases total internal area by 2.5 m²

July-submitted comparison drawing, subject to the decision conditions

What the evidence says
Drawing 3100 compares the parent’s commercial layouts with the guest-accommodation proposal. Its labelled totals are 486.6 m² granted and 489.1 m² proposed gross internal area: a 2.5 m² difference, alongside substantial internal subdivision for bedrooms and en-suites.

Why it may matter — interpretation
Fit-out teams should price the change of layout and room services; the whole 489.1 m² is not additional floor area beyond the parent.

What is not established
Final construction details, installed sanitaryware and equipment procurement are not established.

Inspect the evidence

Commercial corner unit plans and sections, minor amendments · p.1
TOTAL GRANTED ... 486.6m²; TOTAL PROPOSED ... 489.1m² · Issued November 2025 (month only) · 23140 drawing 3100; no revision letter displayed; November 2025 title date; revised proposal received 7 July 2026 · Checked 2026-09-07

TOTAL GRANTED ... 486.6m²; TOTAL PROPOSED ... 489.1m²

The proposed layout separates guest, public and staff bicycle parking

July-submitted access and cycle-parking layout

What the evidence says
The submitted drawing labels 12 secure guest bicycle spaces, six public bicycle spaces and two secure staff spaces serving the ground-floor commercial use. The plan also shows separate commercial and guest entrances.

Why it may matter — interpretation
Cycle-storage and entrance suppliers can distinguish the three users and coordinate secure access arrangements.

What is not established
Installed stands, access-control specification and compliance agreement are not established.

Inspect the evidence

Commercial corner unit plans and sections, minor amendments · p.1
12 guest spaces; 06 public spaces; 2 staff spaces · Issued November 2025 (month only) · 23140 drawing 3100; no revision letter displayed; November 2025 title date; revised proposal received 7 July 2026 · Checked 2026-09-07

12 guest spaces; 06 public spaces; 2 staff spaces

Shopfront and signage details require council agreement

Condition on the July amendment decision

What the evidence says
Condition 4 requires external signage details to be agreed before business begins, with static internal illumination where lighting is needed. It also ties signage, pilasters, plinths and street-front fenestration to the council’s shopfront design guide unless otherwise agreed.

Why it may matter — interpretation
Facade, glazing and sign suppliers need the agreed shopfront detail before settling manufacture and lighting.

What is not established
An agreed signage submission, final grant and installed frontage are not established.

Inspect the evidence

Amendment decision notification and conditions · p.2
Condition 4 · Issued 2026-07-28 · Signed 28 July; notification expressly not final grant · Checked 2026-09-07

Condition 4
Remaining document questions
  • Has the final grant issued, and have the shopfront and signage details been agreed?

The declared pages of these government-published PDFs were visually inspected. Other catalogue files, later compliance, procurement and installed specifications were not established. Historical weekly membership is retained separately from these document dates.

Source history

Timeline

  1. Planning application received

    2660904

  2. Planning decision

    2660904

    Conditional permission

What this record establishes

Only exact linked records appear here. A missing appeal, commencement or completion entry means that evidence has not been established on this page. It does not prove that the event never happened.

Planning scale and individual notice or phase quantities remain separate. Notice quantities are not added into a development total or completion percentage.