Save to pipeline
Connected planning records

Planning case 404020

Dublin City Council · 404020 · Dublin, Dublin

Latest linked evidence

Notified commencement · 2025-12-23

PROTECTED STRUCTURE: Change of use of St. Patrick's Tower from a vacant building to exhibition space and associated works. St. Patrick's Tower is located at the Digital Hub, Thomas Street, Dublin 8. Proposed works include necessary repairs and adaptation of the tower for public use including: 1. Proposed external works: gently sloping access ramps, pedestrian crossings, cobblestone area with benches to the front entrance area, removal of bars from existing ground floor window, replacement of damaged rear window with new louvred vent, new entrance doors, new illuminated signage. 2. Proposed internal works to ground and first floor only, necessary minor repairs to brickwork and repairs to internal roof of entrance lobby area, new floor finish throughout ground floor, new lightweight ceiling finish mounted to underside of existing concrete slab, surface mounted lighting and wiring, mechanical ventilation system with 4 new opes to concrete slab and localized plant on first floor slab.

This page connects records for one planning case. Separate permissions, amendments and phases may belong to a wider development. A notified commencement date does not confirm that building work started.

Source history

Timeline

  1. Planning application received

    404020

  2. Planning decision

    404020

    Permission granted

  3. Grant date recorded

    404020

  4. Notified commencement

    Commencement notice

    PROTECTED STRUCTURE: Change of use of St. Patrick's Tower from a vacant building to exhibition space and associated works. St. Patrick's Tower is located at the Digital Hub, Thomas Street, Dublin 8. Proposed works include necessary repairs and adaptation of the tower for public use including: 1. Proposed external works: gently sloping access ramps, pedestrian crossings, cobblestone area with benches to the front entrance area, removal of bars from existing ground floor window, replacement of damaged rear window with new louvred vent, new entrance doors, new illuminated signage. 2. Proposed internal works to ground and first floor only, necessary minor repairs to brickwork and repairs to internal roof of entrance lobby area, new floor finish throughout ground floor, new lightweight ceiling finish mounted to underside of existing concrete slab, surface mounted lighting and wiring, mechanical ventilation system with 4 new opes to concrete slab and localized plant on first floor slab.

    Quantity not established for this notice.

    · Notice evidence

What this record establishes

Only exact linked records appear here. A missing appeal, commencement or completion entry means that evidence has not been established on this page. It does not prove that the event never happened.

Planning scale and individual notice or phase quantities remain separate. Notice quantities are not added into a development total or completion percentage.