Commencement notice group
Housing commencement notices — Carlow
Carlow, Carlow
1 unique commencement event · latest notified commencement 04 Sep 2026 · planning basis not stated
- Unique commencement events
- 1
- Latest notified commencement
- 04 Sep 2026
- Latest notice
- 280 m²
- Planning references supplied
- None stated
- Public location
- Carlow, Carlow
Planning-anchored public geography
Site identity and location
- Canonical public locality
- Carlow, Carlow
- County
- Carlow
- Approximate commencement source point
Source meaning
What the commencement source confirms
A commencement notice records a declared building-control commencement date. It does not by itself confirm that every permitted work began or was completed.
Dates, scale and organisations below stay attached to the individual notice that supplied them.
Official sources
Official planning documents
No planning reference is supplied for this notice group.
These links are source-backed navigation. The notice-supplied planning reference remains separate from any verified canonical planning relationship.
Chronological source evidence
Commencement notice timeline
This record remains its own commencement notice group because no shared planning-reference context is available. The grouping does not establish construction progress or completion.
Works consist of internal alterations, reconfiguration, and fire safety upgrades of an existing residential property from an 8 bedroom residence to an 8-bedroom, shared residential property. For the purposes of the Building Regulations (specifically Technical Guidance Document B - Fire Safety), the building is categorized under Purpose Group 2(b) ('Other Residential'). Scope of Works Includes: Construction of non-loadbearing fire-rated stud partition walls to form bedroom/en-suite facilities. Installation of an upgraded, fully addressable mains-powered Fire Detection and Alarm System to IS 3218 (Type L2/L1). Installation of an Emergency Lighting System throughout internal escape routes to IS 3217. Upgrades to compartmentation and internal escape routes, including the installation of FD30S fire door assemblies fitted with self-closing devices, intumescent strips, and cold smoke seals. Provision of specialist passive fire-stopping to all mechanical and electrical service penetrations. Omission/removal of the external steel fire escape stairs and associated minor external window/door adjustments to the rear elevation. All works are internal or minor external items and do not involve structural footprint extensions
Floor area stated for this source: 280 m².
A commencement notice records a declared building-control commencement date. It does not by itself confirm that every permitted work began or was completed. Future verified planning enrichment can be added to this record without changing its notice evidence.