Dublin City Council / 2150/19Sub03

Protected structure, Nos. 1-2 Upper O'Connell Street & No. 29 North Earl Street... - Planning Application 2150/19Sub03

3. The applicant shall comply with the following requirements of the Conservation Section: iv. The removal of all existing timber floorboards from the...

Source: Dublin City Council public planning register

Record 2150/19Sub03. Direct source URL supplied by the public planning feed. Use the authority file for final verification before acting.

Open source record

Development Description

3. The applicant shall comply with the following requirements of the Conservation Section: iv. The removal of all existing timber floorboards from the building for reuse elsewhere contravenes best conservation practice and is not permitted without detailed justification. Reason: To protect the fabric, character and integrity of this protected structure

H&S triggerProtected structure

Map

No coordinates supplied in the public planning feed.

Same county

Related leads nearby

5 records
Dublin City Council / WEB2460/26 / 12 Jun 2026

74, Amiens Street, Dublin 1, D01 E8N1

PROTECTED STRUCTURE : change of use of the existing building from office use to residential use, together with all associated internal alterations, conservation and restoration works, building services, and ancillary works necessary to facilitate the propos...

Stage
New Application
Applicant
John Curtin
Units / floor
units unknown / floor unknown
Useful for
ComplianceConservation specialistHealth & SafetyPlanner/Consultant
Agent
Roger Bell
H&S triggerProtected structureVacant / reuse signal

Source: Dublin City Council public planning register / official file linked

Dublin City Council / 2918/21Sub02 / 10 Jun 2026

Ormond Court, 11/11A Ormond Quay Lower, Dublin 1, D01 K2X9

8. The developer shall comply with the following conservation requirements: h) Drawings shall be submitted for agreement indicating historic floorboards to be retained, when all lifting of existing floor boards establishes the condition and extent of histor...

Stage
New Application
Applicant
Collen Investment Ltd
Units / floor
units unknown / floor unknown
Useful for
ComplianceConservation specialistHealth & SafetyPlanner/Consultant
Agent
Lawrence Long Architects
H&S triggerProtected structure

Source: Dublin City Council public planning register / official file linked

5. The following requirements of the Planning Authority’s Conservation Section shall be fully complied with in the proposed development: c) During the course of the development, the applicant shall submit for the written approval of the planning authority: ...

Stage
New Application
Applicant
Christopher Sheehan
Units / floor
units unknown / floor unknown
Useful for
ComplianceConservation specialistHealth & SafetyPlanner/Consultant
Agent
Sheehan & Barry Architects
H&S triggerProtected structure

Source: Dublin City Council public planning register / official file linked

Dublin City Council / 3731/23 / 22 Jun 2026

Dublin

PROTECTED STRUCTURE: (RPS. 3300) works include the demolition of a single storey, light industrial building, located within stone boundary walls, with the part retention of blockwork wall forming the east boundary of the site. Removal too of a roller shutte...

Stage
Commencement
Est. value band
€<250k
Applicant
not available yet
Units / floor
1 unit / 167 m²
Useful for
ComplianceConservation specialistHealth & SafetyPlanner/Consultant
Agent
not available yet
H&S triggerProtected structureGoing to sitesource=commencement

Source: Owner-supplied commencement export / source record not directly linked

Lead page Map
Dublin City Council / WEB5177/25 / 19 Jun 2026

Dublin

PROTECTED STRUCTURE: A) Cleaning of the existing granite and brick facades, granite entrance steps and granite sills; repointing of existing front elevation to include localised repairs, repointing of entrance steps and repointing and reflaunching of chimne...

Stage
Commencement
Applicant
not available yet
Units / floor
units unknown / 185 m²
Useful for
ComplianceConservation specialistHealth & SafetyPlanner/Consultant
Agent
not available yet
H&S triggerProtected structureGoing to sitesource=commencement

Source: Owner-supplied commencement export / source record not directly linked