Back to leads
Further Information

Protected structure, 32-33 Blessington Street, Dublin 7 - Planning Application WEB1681/26

Dublin / Dublin 7 / 32-33 Blessington Street, Dublin 7

Est. value €250k–500k
Units Not listed
Floor area 440 m²
Decision due 29 Jun 2026

Source-linked planning record

Protected structure, 32-33 Blessington Street, Dublin 7 - Planning Application WEB1681/26

Dublin / Dublin 7 / 32-33 Blessington Street, Dublin 7
PB ref
PB--3433094532
Plan ref
WEB1681/26
Authority
Dublin City Council
Stage / date
Further Information / 29 Jun 2026
Est. value band
€250k–500k
Units / floor
440 m²
Project class
Protected structure
Promoter
not available yet
Architect / agent
not available yet

Source: /organisations/dublin-city-council/

Key facts

Lead summary

Source
Dublin City Council public planning register
Planning authority
Dublin City Council
Application reference
WEB1681/26
Applicant
not available yet
Agent
not available yet
Decision stage
Further Information
Decision due
29 Jun 2026
Floor area
440 m²

Official description

Verbatim source text

PROTECTED STRUCTURE: RETENTION AND PERMISSION: Planning Permission is sought to consolidate Change of Use from Tourist hostel to Community Services Administration Offices (440 sq m) and to complete minor works comprising of: the amalgamation of front meeting rooms and lobbies on all levels replacing 4 no. access doors with fire rated studs within existing openings, amalgamation of kitchen & dining at basement level of unit 32. Floors, walls and ceilings to be made good with new painted finishes and carpet tile floor finishes. Existing electrical installation to be repaired and replaced with new energy efficient lighting (suspended track lights under historic ceilings / surface mounted on modern ceilings under attic) and electrical services (including surface mounted dado trunking). Existing windows to be repaired with replacement of any damaged windowpanes. External basement areas and steps to be repaired and repainted. Water ingress to external rear walls to be remedied including removal of redundant surface mounted external pipework- repairing/ sealing existing rainwater downpipes, making good to all associated internal and external surfaces. Retention Permission is sought for works undertaken to date being the removal of modern sanitary installations within the meeting rooms of all the main upper floors, associated removal of modern stud partitions and doors, removal of modern sheet floor finishes and loose insulations.

Verify against official source

Project team

Named source parties

Promoter
not available yet
Planning agent
not available yet

Lifecycle timeline

Application to site progress

  1. Applied

    24 Mar 2026 WEB1681/26
  2. Decision

    Grant Permission 26 Jun 2026
  3. Commenced

    No commencement indexed Owner-export and BCMS records are indexed only when a reliable source link exists.
  4. Completed

    Completion not recorded Smaller works often do not require a completion certificate.

Likely trades & supplier leads

Inferred from scheme type and scale

ComplianceConservation specialistFire SafetyHealth & SafetyPlanner/ConsultantSecurity
Board this lead Create alert