Infrastructure · Co. Galway

Coill Rua Thiar, Mylan Teoranta, Indreabhán, Co. Galway

Decision to grant 11 Aug 2026

Get updates on this application

We'll email you when building work starts.

We send a confirmation link first. Nothing starts until you click it. You can stop at any time.

Key facts

  • Planning application 2661003 at Coill Rua Thiar, Mylan Teoranta, Indreabhán, Co. Galway: 1 No. engineering store building.
  • The applicant is Mylan Teoranta. The agent is Nj Kearns & Co Ltd Architects.
  • It was received by Galway County Council on 18 Jun 2026.
  • Status: Decision to grant 11 Aug 2026.
  • The council decided on 11 Aug 2026 to grant permission. Final grant not yet recorded. No site start has been filed yet.

Source: the Galway County Council planning register, checked 2 Sep 2026. Open the council's file

More planning applications in Indreabhan · Planning applications in Co. Galway

What and where

1 No. engineering store building

of 1 No. engineering store building, 3 No. engineering store containers, 1 No. contractor portacabin, 2 No. waste sorting containers, 1 No. pump house building, 1 No. diesel generator building, 4 No. pre-fabricated office buildings, 1 No. single storey extension to building B2, 1 No. Nitrogen generator, 3 No. waste storage container, 3 No. temperature control chambers, 1 No. bottled gas storage, 1 No. electrical substation building, 1 No. chemical store, and 1 No. bunded oil tank and retention of car park to the North of the site

Description as published by the council. Its text starts part-way through a sentence.

Location
Indreabhan, Co. Galway Map
Planning reference
2661003
Applicant
Mylan Teoranta

Numbers and dates

Homes
~1estimated from the application
Project type
Infrastructure
Received
18 Jun 2026
Decision to grant
11 Aug 2026Final grant not yet recorded

Timeline

  1. Application received
  2. Decision to grant

Outlook

What happens next

The council decided on 11 Aug 2026 to grant permission. Final grant not yet recorded. No site start has been filed yet.

An outlook from the planning record, not a tender or a confirmed start date.

Documents and evidence

Check the record

  • Council planning fileThe application file 2661003 on eplanning.ie: drawings, reports and the decision.Open the council's file

Reviewed build intelligence

What the documents establish

Government document review

Council retention decision 11 August 2026, followed by an exact Commission appeal notification dated 3 September and received4 September. No appeal outcome or final grant is established.

5 official documents inspected · Checked 2026-09-06 · Official file index

The decision concerns existing industrial structures and equipment

Retention decision appealed; existing equipment is not a new installation package · Mylan Teoranta, Galway County 2661003; retention rather than a new industrial expansion

What the evidence says
The 11 August 2026 decision is for retention of existing engineering stores and containers, a pump house, diesel-generator building, prefabricated offices, a nitrogen generator, temperature-control chambers, electrical substation, chemical storage and other listed works. Condition 2 confines it to the scheduled works and excludes intensification or change of use without prior permission. The notification expressly is not a final grant.

Why it may matter — interpretation
Industrial engineers and suppliers can separate an existing-asset compliance review from a new equipment requirement.

What is not established
Current operating condition, replacement plans, equipment orders and final appeal outcome are unverified.

Inspect the evidence

Mylan retention: council notification of decision · p.2
No intensification or change of use · Issued 2026-08-11 · Thirteen conditions; expressly not a final grant; subsequently appealed · Checked 2026-09-06

No intensification or change of use

Mylan retention: council notification of decision · p.1
decided to grant RETENTION · Issued 2026-08-11 · Thirteen conditions; expressly not a final grant; subsequently appealed · Checked 2026-09-06

decided to grant RETENTION

The Commission notification binds this retention case to appeal 502026

Retention decision appealed; existing equipment is not a new installation package · Exact authority/reference relationship established by the Commission notification

What the evidence says
A Commission letter dated 3 September 2026 and received by the council on 4 September explicitly identifies PL-502026-GY-26 and planning reference 2661003. It encloses an appeal and requests the planning file. This establishes a later appeal event after the retention decision; it does not establish an appeal outcome or that every ground in the enclosed submission has been accepted.

Why it may matter — interpretation
Planning and technical teams can follow the correct appeal before relying on the council conditions as the final position.

What is not established
An appeal determination, later revisions and a final grant are unverified. The Commission website case page has not been independently confirmed.

Inspect the evidence

Commission appeal notification to Galway County Council · p.1
PL-502026-GY-26 · Issued 2026-09-03 · PL-502026-GY-26; received4 September 2026; only the official notification page reviewed · Checked 2026-09-06

PL-502026-GY-26

The nitrogen generator is shown in an existing metal container

Retention decision appealed; existing equipment is not a new installation package · Existing nitrogen enclosure, drawing 1783-P-13 received 18 June 2026

What the evidence says
May drawing 1783-P-13 depicts an existing nitrogen-generator container approximately 6.020 m by 2.400 m, with metal-container walls and a metal roller shutter. It is an enclosure drawing for retention, not a nitrogen-generation capacity or process-equipment specification.

Why it may matter — interpretation
Process engineers can locate the retained nitrogen enclosure while identifying the process specifications still needed for any assessment.

What is not established
Gas purity, flow, pressure, generator model, ventilation performance and current operational condition are unverified.

Inspect the evidence

Mylan retention: nitrogen-generator enclosure · p.1
METAL ROLLER SHUTTER · Issued May 2026 (month only) · 1783-P-13; received 18 June 2026; existing enclosure · Checked 2026-09-06

METAL ROLLER SHUTTER

The diesel drawing specifies a building, not a generator rating

Retention decision appealed; existing equipment is not a new installation package · Existing diesel-generator enclosure, drawing 1783-P-10

What the evidence says
May drawing 1783-P-10 shows an existing diesel-generator building about 7.685 m by 4.700 m with metal cladding, a concrete slab and an adjacent gas-cylinder cage. It provides no generator electrical rating, fuel-consumption figure or verified commissioning record.

Why it may matter — interpretation
Building and plant engineers can check enclosure materials and dimensions without mistaking the drawing for a selected generating set.

What is not established
Generator model, output, acoustic performance, exhaust arrangement and installed equipment condition are unverified.

Inspect the evidence

Mylan retention: diesel-generator building · p.1
METAL CLADDING SHEETING · Issued May 2026 (month only) · 1783-P-10; received 18 June 2026; existing building · Checked 2026-09-06

METAL CLADDING SHEETING

One retained chamber drawing identifies insulated walls and PVC sheeting

Retention decision appealed; existing equipment is not a new installation package · One selected existing chamber; the three-chamber permission description remains separate

What the evidence says
Drawing 1783-P-25 depicts one existing temperature-control chamber about 12.100 m by 3.770 m, with PVC sheeting over insulated walls and a concrete step. The decision lists three chambers overall, but this selected drawing is not used to multiply the dimensions or infer the other chambers’ construction.

Why it may matter — interpretation
Envelope and temperature-control specialists can distinguish the documented enclosure from the unreviewed chambers and missing thermal performance data.

What is not established
Insulation type or thickness, operating temperature, refrigeration plant, other chamber details and thermal performance are unverified.

Inspect the evidence

Mylan retention: temperature-control chamber · p.1
PVC SHEETING OVER INSULATED WALLS · Issued May 2026 (month only) · 1783-P-25; received 18 June 2026; one existing chamber · Checked 2026-09-06

PVC SHEETING OVER INSULATED WALLS

The conditions retain existing drainage and require treatment-plant maintenance

Retention decision appealed; existing equipment is not a new installation package · Council-conditioned version under appeal; existing wastewater connection and treatment plant

What the evidence says
Conditions 5 and 6 refer to the existing stormwater and foul-sewer connections, require only uncontaminated stormwater to enter the public drain, and require an annual maintenance arrangement and records for the treatment plant. They do not provide a new treatment-plant design, capacity or confirmed compliance history.

Why it may matter — interpretation
Facilities and wastewater engineers can identify the maintenance-record requirement and distinguish it from a new treatment package.

What is not established
Plant capacity, treatment technology, maintenance records and current discharge compliance are unverified.

Inspect the evidence

Mylan retention: council notification of decision · p.3
ongoing maintenance of the treatment plant · Issued 2026-08-11 · Thirteen conditions; expressly not a final grant; subsequently appealed · Checked 2026-09-06

ongoing maintenance of the treatment plant

Mylan retention: council notification of decision · p.2
existing stormwater network · Issued 2026-08-11 · Thirteen conditions; expressly not a final grant; subsequently appealed · Checked 2026-09-06

existing stormwater network

The council condition sets a 20 percent charging-space requirement

Retention decision appealed; existing equipment is not a new installation package · Condition 9 in the appealed council decision; car-park retention

What the evidence says
Condition 9 states that 20 percent of the total car-parking spaces must provide for EV charging points and be demarcated with appropriate signage. No charger count is calculated because a verified parking denominator and charger schedule are not established in the inspected pages.

Why it may matter — interpretation
Electrical designers can check the charging-space requirement against the final parking schedule before sizing infrastructure.

What is not established
Final parking denominator, appeal amendments, charger count, power rating and installed provision are unverified.

Inspect the evidence

Mylan retention: council notification of decision · p.3
20% · Issued 2026-08-11 · Thirteen conditions; expressly not a final grant; subsequently appealed · Checked 2026-09-06

20%
Remaining document questions
  • Which later official decision, approved detail or revision changes these source-specific findings?
  • Has a phase-specific official record established the selected equipment or installed specification?

Selected pages of 5 government-published PDFs were visually inspected. 75 catalogue rows retained and six PDFs retrieved. Selected pages of five PDFs support these findings. Only the official notification page of the 10-page appeal correspondence was reviewed; personal appeal grounds were not extracted. Proposals do not establish procurement or installed work.

How we know this

From the Galway County Council planning register, checked 2 Sep 2026. We link to the council's own file so you can check the official record before you act. Facts from the planning documents were read from the documents in that file.

Explore the area

More planning activity near Indreabhan

Get alerts for IndreabhanFree. We email you when new applications appear.

Free email alerts

Get new Indreabhan projects by email

New applications, decisions and site starts in Indreabhan, Co. Galway. Only when there is something new.

We send a confirmation link first. Nothing starts until you click it. You can unsubscribe at any time.

Email alerts for this applicationMore alert options