Forgney, Ballymahon, County Longford, N91 TPN3, Longford
Forgney, Ballymahon, County Longford, N91 TPN3
the change of use and conversion of an existing detached domestic garage to a two bedroom dormer dwelling, together with all associated elevational alterations, internal modifications, connection to existing services, site works, landscaping, and all ancillary works necessary to facilitate the development
- The site is located within Rural Areas Under Strong Urban Influence, where the National Planning Framework, the Regional Spatial and Economic Strategy and the Longford County Development Plan 2021–2027 require that new housing in the open countryside be strictly limited to persons with a demonstrable economic or social need to reside in the rural area. The applicant’s rural housing need has already been met through the existing permitted dwelling on the landholding (Reg. Ref. PL24/60187). The proposed conversion of a domestic garage—permitted solely as an ancillary structure—to a second independent dwelling would constitute overdevelopment of the site and would contribute to urban-generated housing pressure in a controlled rural area. The Planning Authority is not satisfied that any additional rural housing need exists to justify a second dwelling. The proposed development would therefore be contrary to the proper planning and sustainable development of the area.
- The applicant has failed to demonstrate that adequate wastewater treatment and disposal arrangements exist on the site. The submitted Site Characterisation Report is based on an outdated 2014 assessment prepared under the superseded EPA Code of Practice (2009) and does not comply with the EPA Code of Practice (2021). In the absence of updated percolation testing, population-equivalent calculations and confirmation of the operational status of the existing Bison treatment system, the Planning Authority is not satisfied that the proposed development would not give rise to a risk of pollution. Development of the kind proposed would therefore be premature by reference to an existing deficiency in sewerage facilities, contrary to the proper planning and sustainable development of the area.
- The applicant has failed to demonstrate that the proposed development would not endanger public safety by reason of traffic hazard, obstruction of road users and inadequate access with the site. No sightline drawings, entrance geometry details or surface water drainage proposals have been submitted. The Planning Authority is therefore not satisfied that the proposed development would provide an acceptable standard of traffic safety and would be contrary to the proper planning and sustainable development of the area.