New Application · decision due 13 Nov 2026Protected structurePre-decision · not yet granted

Protected structure, 13 Highfield Road, Rathgar, Dublin 6

Dublin 6, Dublin · Dublin City Council · Plan WEB2238/26Sub02 · PB ref PB-2031714200

3. Prior to the commencement of development, the applicant/developer shall submit the following details to the Planning Authority for written agreement: a) Revised roof plans and elevations at 1:50 scale, including: • The solar panel location shall be reviewed. The solar panels shall be omitted from the east and west...

Indicative value Not listed PB indicative band
Units applied for Not listed public application record
Floor area Not listed no reliable figure indexed
Decision due 13 Nov 2026 public planning date
Commenced None indexed public commencement index
Applied for, not granted

The record describes what is sought. Nothing is permitted until the authority decision.

Protected structure

The protected-structure designation is source evidence and can shape specification and method.

Not procurement evidence

No tender, award, contractor appointment, supplier appointment or procurement timetable is inferred.

Opportunity & supplier intelligence

What is known, and what may happen next

Source-linked

Timing is a planning-stage outlook, not a tender, award, contractor appointment, supplier appointment or guaranteed procurement date.

Likely procurement timing Post-decision monitoring

A planning decision is recorded and no linked commencement is indexed. Conditions, procurement and start timing remain unconfirmed.

Decision date 17 Aug 2026. / Confidence: Low
Decision Decision recorded

Decision date 17 Aug 2026.

Open evidence
Commencement activity No linked activity indexed

No commencement indexed / This is an index state, not proof that no works have started.

Source limited
Drawings availability Drawing availability not indexed

No drawing entry is available in this lead's bounded document evidence.

Source limited

Confirmed application scope

3. Prior to the commencement of development, the applicant/developer shall submit the following details to the Planning Authority for written agreement: a) Revised roof plans and elevations at 1:50 scale, including: • The solar panel location shall be reviewed. The solar panels shall be omitted from the east and west elevations and limited to the central valley and the roof of the sunroom only unless otherwise agreed in writing. • Additional details of the existing decorative fish-scale slate coursing. The...

Ref WEB2238/26Sub02 Source-linked Official application description for exact planning reference WEB2238/26Sub02
Open scope evidence

Public source roles

No named firm role is published in this panel's source contract. PlanningBrief does not infer a contractor or supplier.

Explicit source signals only

2 packages
Conservation

Protected-structure / conservation scope

The public application description explicitly references protected-structure / conservation scope.

WEB2238/26Sub02 Explicit description / Source-linked Source
Services

Services / drainage scope

The public application description explicitly references services / drainage scope.

WEB2238/26Sub02 Explicit description / Source-linked Source
Confidence & provenance 1 official source
Authority
Dublin City Council
Exact reference
WEB2238/26Sub02
Evidence reviewed
26 Sep 2026
Confidence
Source-linked

Facts come from the indexed public planning record and any bounded structured document evidence. No request-time official fetch, tender, award or appointment inference is used.

Application-stage scope

What the public record evidences

3 source-supported signals
Protected structure

Protected structure

The public application record identifies protected structure in the submitted planning scope.

WEB2238/26Sub02Explicit application record
Conservation

Protected-structure / conservation scope

The public application description explicitly references protected-structure / conservation scope.

WEB2238/26Sub02Explicit description signal
Services

Services / drainage scope

The public application description explicitly references services / drainage scope.

WEB2238/26Sub02Explicit description signal

Only source-supported scope signals are shown; generic trade padding is omitted.

Project facts

Named source parties

Promoter
Dermot & Yvonne Rafter
Planning agent
Michael Malone
Official description

Application text

3. Prior to the commencement of development, the applicant/developer shall submit the following details to the Planning Authority for written agreement: a) Revised roof plans and elevations at 1:50 scale, including: • The solar panel location shall be reviewed. The solar panels shall be omitted from the east and west elevations and limited to the central valley and the roof of the sunroom only unless otherwise agreed in writing. • Additional details of the existing decorative fish-scale slate coursing. The fish-scale slates shall be retained and reinstated on a like-for-like basis in accordance with the documented original pattern. • Omission of the proposed in-line (integrated) solar panels. A revised specification shall be submitted for conventional PV panels mounted on brackets above the retained slate roof covering. b) Detailed drawings and specifications at 1:10 scale of the proposed rooflight, including materials and colour finishes. The rooflight shall be a conservation-style rooflight. Details and methodologies for repairs to existing lath-and-plaster ceilings and roof rafters shall also be submitted. c) Details shall be submitted demonstrating the impact of the proposed PV installation on the structural and historic fabric of the building. The submission shall include method statements and material specifications, details of any structural interventions required, the location of all associated equipment including pipe runs, hot water tanks and ancillary infrastructure, the location of any solar batteries and associated fire safety measures, details of any alarm or monitoring systems, and information on how services, fixings and other installations will be accommodated while minimising impacts on the historic fabric of the Protected Structure.

Source-aware chronology

Application to site progress

Empty lanes explain their state.
AppealsAn Coimisiún Pleanála
  1. Appeal No appeal possible yet The application has not been decided.
CommencementPublic commencement index
  1. Commenced No commencement indexed A scheme cannot start before it is permitted.
CompletionPublic completion projection
  1. Completed Completion not recorded No privacy-cleared exact completion certificate is linked to this permission. Absence is not evidence that the project is incomplete.
Evidence register

Source, scope and limits

Public planning record
Application description and scale WEB2238/26Sub02

3. Prior to the commencement of development, the applicant/developer shall submit the following details to the Planning Authority for written agreement: a) Revised roof plans and elevations at 1:50 scale, including: • The solar panel location shall be reviewed. The solar panels shall be omitted from the east and west elevations and limited to the central valley and the roof of the sunroom only unless otherwise agreed in writing. • Additional details of the existing decorative fish-scale slate coursing. The fish-scale slates shall be retained and reinstated on a like-for-like basis in accordance with the documented original pattern. • Omission of the proposed in-line (integrated) solar panels. A revised specification shall be submitted for conventional PV panels mounted on brackets above the retained slate roof covering. b) Detailed drawings and specifications at 1:10 scale of the proposed rooflight, including materials and colour finishes. The rooflight shall be a conservation-style rooflight. Details and methodologies for repairs to existing lath-and-plaster ceilings and roof rafters shall also be submitted. c) Details shall be submitted demonstrating the impact of the proposed PV installation on the structural and historic fabric of the building. The submission shall include method statements and material specifications, details of any structural interventions required, the location of all associated equipment including pipe runs, hot water tanks and ancillary infrastructure, the location of any solar batteries and associated fire safety measures, details of any alarm or monitoring systems, and information on how services, fixings and other installations will be accommodated while minimising impacts on the historic fabric of the Protected Structure.

AuthorityDublin City Council
ReferenceWEB2238/26Sub02
StatusChecked 26 Sep 2026
Open official record